Publication:
Novel Possibilities for the Diagnosis of Fetal Distress in Pre-eclamptic Women

dc.contributor.authorLakhno, Igor
dc.date.accessioned2023-04-25T15:07:23Z
dc.date.available2023-04-25T15:07:23Z
dc.date.issued2015-08-01
dc.description.abstractObjective Fetal deterioration has been known as a result of acute or chronic disturbances in the system of ‘motherplacenta- fetus’. Pre-eclampsia (PE) is a maternal gestational disease caused by abnormal placentation that could provoke fetal distress. Aim The aim of the investigation was to survey the accuracy of fetal distress diagnostics in case of traditional cardiotocography (CTG) waveform evaluation and electrocardiography (ECG) parameters analysis obtained from maternal abdominal signal before and during labor in pre-eclamptic patients. Materials and methods One hundred and thirty-nine pregnant ladies at 32 to 40 weeks of gestation were enrolled in the study. There were 30 women with physiological pregnancy and normal fetal condition according to hemodynamic Doppler values and fetal ECG parameters in group I. In group II, 64 patients with mild and moderate PE were involved whom were performed fetal ECG noninvasive monitoring and hemodynamic Doppler. In group III, 45 patients with severe PE were monitored with fetal noninvasive ECG and hemodynamic Doppler. Results It was determined that fetal autonomic tone was suppressed with the relative increase of low frequency branch in pre-eclamptic patients. The increased value of the amplitude of mode and stress index was associated with abnormal myocardial adrenergic stimulation. It has induced pQ and QT shortening, increased T/QRS ratio. Fetal cardiac response was determined as gradual reduce of autonomic regulation. The most considerable negative correlation was determined in pair Apgar score 1 vs T/QRS (R = – 0.48; p < 0.05). The QT interval duration has revealed positive correlation with Apgar score 1 (R = 0.44; p < 0.05). Additional to the conventional CTG analysis evaluation of noninvasive fetal ECG parameters has contributed to better diagnostic of distress. Conclusion Fetal noninvasive ECG has showed sensitivity 100.0% and specificity 93.8% and, therefore, was more accurate and convenient method for fetal monitoring than conventional CTG.en_US
dc.identifier.citationLakhno I. V. Novel Possibilities for the Diagnosis of Fetal Distress in Pre-eclamptic Women / I. V. Lakhno // International Journal of Infertility and Fetal MedicineInt. – 2015. – Vol. 6, No 2. – P. 62–66.en_US
dc.identifier.issn2229-3817
dc.identifier.urihttps://repo.knmu.edu.ua/handle/123456789/31942
dc.language.isoenen_US
dc.publisherJaypee Brothersen_US
dc.subjectfetal distressen_US
dc.subjectfetal noninvasive ECG monitoringen_US
dc.subjectpre-eclampsiaen_US
dc.titleNovel Possibilities for the Diagnosis of Fetal Distress in Pre-eclamptic Womenen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication515b1fe6-d88e-4687-8de8-707e4fca1a75
relation.isAuthorOfPublication.latestForDiscovery515b1fe6-d88e-4687-8de8-707e4fca1a75

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
ijifm-2015-06-062.pdf
Size:
506.52 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
11.22 KB
Format:
Item-specific license agreed upon to submission
Description: